10mm Copper Bonded Conductor -Hyderabad
or 4 interest-free installments by Afterpay. More Info
Description
Description
10mm Copper Bonded Conductor in Hyderabad | Data Center & Power Infrastructure Earthing
Hyderabad soil is largely granite-based with high resistivity (80–200 Ω-m). Rapid growth in data centers, pharma, and power infrastructure demands earthing systems with long-term conductivity and corrosion resistance.
Product Overview & Working Principle
What is a 10mm Copper Bonded Conductor?
A 10mm copper bonded conductor consists of a high-tensile low-carbon steel core metallurgically bonded with 99.9% pure electrolytic copper. Unlike copper-clad or coated wires, the molecular bond ensures no peeling, cracking, or galvanic separation, even under thermal cycling and fault conditions.
How It Works in Earthing Systems?
-
The steel core provides mechanical strength and deep-driving capability.
-
The thick copper layer ensures excellent conductivity and corrosion resistance.
-
When installed in earth grids, vertical electrodes, or ring mains, it dissipates fault and lightning currents safely into soil, stabilizing touch and step potentials.
Technical Specifications (10mm Copper Bonded Conductor)
| Parameter | Specification |
|---|---|
| Nominal Diameter | 10 mm |
| Core Material | Low carbon steel |
| Copper Purity | ≥ 99.9% electrolytic copper |
| Copper Bonding | Molecular (continuous metallurgical bond) |
| Copper Thickness | As per IEC 62561 |
| Tensile Strength | ≥ 600 N/mm² |
| Electrical Conductivity | High (stable under fault currents) |
| Standard Lengths | Coils / cut lengths (project-specific) |
| Operating Environment | Indoor / Outdoor / Buried |
| Expected Service Life | 30–40 years (soil dependent) |
Performance & Engineering Advantages
Proven Performance in Indian Conditions of 10mm Copper Bonded Conductor
Low Earth Resistance: Optimized conductor geometry delivers reliable resistance values in 10–200 Ω-m soils.
-
Corrosion Resistance: Copper layer resists chlorides (coastal belts) and acidic soils during monsoons.
-
High Fault Current Capacity: Safely carries short-circuit and lightning surge currents without deformation.
-
Mechanical Robustness: Steel core prevents stretching or breakage during trenching and backfilling.
Standards & Compliance
| Standard / Authority | Compliance |
|---|---|
| IS 3043 | Code of Practice for Earthing |
| IEC 62561 | Lightning Protection Components |
| CEA Guidelines | Electrical Safety & Earthing |
| CPWD Specifications | Govt. & PSU projects |
| DISCOM Requirements | Utility-approved earthing |
*All products supplied via EarthingMart are accompanied by test certificates, material traceability, and GST invoices.
Applications & Use Cases
-
-
-
-
Hyperscale Data Center, HITECH City
-
Project Type: Tier-III Data Center
-
Challenge: Very high soil resistivity, strict uptime norms
-
Solution: Multi-point earthing grid using 10mm copper bonded conductor
-
Result:
-
Achieved ≤0.6 Ω earth resistance
-
Stable grounding for UPS & server systems
-
Zero downtime due to earthing faults
-
-
-
-
-
Why Buy from EarthingMart? (Supplier Advantage)
| Parameter | EarthingMart | Typical Market Vendors |
|---|---|---|
| Engineering Support | ✔ Dedicated earthing experts | ✖ Limited |
| Standards Compliance | ✔ IS & IEC documented | △ Often unclear |
| Stock Availability | ✔ Ready stock | ✖ Made-to-order |
| Pan-India Delivery | ✔ Yes | △ Regional |
| Bulk Project Pricing | ✔ Transparent | ✖ Inconsistent |
| Documentation | ✔ Datasheets & test reports | △ Partial |
| After-Sales Support | ✔ Technical assistance | ✖ Minimal |
Installation & Maintenance Guidance (Best Practices)
Installation Guidelines
-
Lay conductor in trenches (minimum 600 mm depth) or as per design.
-
Use exothermic welding or approved clamps for joints—avoid loose mechanical connections.
-
Ensure proper backfill (bentonite/earthing compound) in rocky or dry soils.
-
Maintain continuous loops for ring earthing systems.
Maintenance Recommendations
-
Periodic earth resistance testing (annual or pre-monsoon).
-
Visual inspection of accessible joints.
-
No routine replacement required due to copper-bonded construction.
FAQs – 10mm Copper Bonded Conductor
1. Can 10mm copper bonded conductor reduce high soil resistivity?
Yes, especially when paired with earthing compounds.
2. Is it recommended for data centers?
Yes. Preferred for sensitive electronic installations.
3. Is it accepted by Telangana DISCOMs?
Yes, when installed as per IS 3043.
4. Does EarthingMart support large infra projects in Hyderabad?
Yes. Dedicated technical & logistics support provided.
5. What jointing method is recommended?
Exothermic welding is preferred for permanent, low-resistance joints.
7. Is it suitable for solar plants?
Yes. Widely used in utility-scale and rooftop solar projects across India.
8. Do you provide bulk pricing?
Yes. EarthingMart offers project-based bulk pricing and logistics support.
9. Is technical support available?
Yes. Dedicated earthing experts assist with design and product selection.